GYTA(GYFTA)
Review
Description

GYTA(GYFTA)
Temperature Range
Transport/Storage temp:-40℃~+70℃
Installation temp:-30℃~+50℃
Operation temp:-40℃~+70℃
Structural Characteristics | |||
Fiber count | 2~288 | Waterproof layer | Cable core filled with cable gel or water blocking tape,water blocking yarns |
Loose tude | Colored fiber in PBTloose tude,filled with fiber gel | Corrugated aluminum-plastic tape | Enhances cable's moisture proof performance and ensures cable's flexibility and anti-bending capability |
Gentral Strength member | Steel wire or FRP(fiber reinforce plastic rod) | Sheath | Polyethylene(PE) |
Technical Data | ||||||||
Fiber count | Cable outer dia (mm) | Cable weight (kg/km) | Min.bending radius(mm) | Permissble tensile force(N) | Permissble pressure force (N/100mm) | |||
Static | Dynamic | Short-term | Long-term | Short-term | Long-term | |||
2-36 | 10.5 | 93 | 10D | 20D | 1500 | 600 | 1000 | 300 |
38-72 | 11.1 | 105 | 10D | 20D | 1500 | 600 | 1000 | 300 |
74-84 | 11.8 | 118 | 10D | 20D | 1500 | 600 | 1000 | 300 |
86-96 | 12.4 | 130 | 10D | 20D | 1500 | 600 | 1000 | 300 |
98-108 | 13.1 | 154 | 10D | 20D | 1500 | 600 | 1000 | 300 |
132-144 | 15.2 | 200 | 10D | 20D | 1500 | 600 | 1000 | 300 |
288 | 18.2 | 305 | 10D | 20D | 1500 | 600 | 1000 | 300 |
"D"is cable dianeter | ||||||||
All sizes and performance values can be specified by customer. |